The Styrkholm Spec

Built to a standard you can check.

Most builders sell shelters with adjectives. We publish numbers. Here is how a Styrkholm compound compares with what is commonly sold, and with the standards set by FEMA, the EPA, NFPA and Swiss civil protection.

SystemCommonly soldThe benchmarkThe Styrkholm Spec
StructureAny buried box, often a shipping containerEngineered for soil and groundwater loadsDesigned by a licensed engineer for the site's soil, depth and water table, with stamped drawings. No shipping containers.
Fresh air per personPassive vent pipe or small fanFEMA historic minimum 3 cfm; Oak Ridge guidance about 40 cfm in hot weatherVentilation sized for hot-weather occupancy at about 40 cfm per person, filtered.
Air filtration chainFilter box on the intakeSwiss shelters: blast valve, pre-filter, blower, NBC filter, overpressure valve, airlockThe complete chain, HEPA plus impregnated carbon, positive pressure, airlock, and a hand-crank backup for the blower.
Carbon dioxideNot addressedAbout 1 cfm per person minimum even in cold weatherContinuous CO2 monitoring with alarm in every occupied below-grade room.
Radiation shieldingUnstatedEach 2.2 in. of concrete or 3.3 in. of packed earth roughly halves gamma radiationSleeping and living quarters designed for a protection factor of about 1,000, roughly ten halving thicknesses of mass.
RadonNot mentionedEPA action level 4 pCi/L; consider fixing from 2 pCi/LSub-slab mitigation built in, with every below-grade space tested after occupancy and brought below 2 pCi/L.
MoistureWaterproof coatingGround holds about 40 to 70°F year round, so condensation is the common failureMembrane waterproofing, perimeter drainage and dehumidification sized for full occupancy.
WaterA few cases of bottled waterReady.gov: 1 gallon per person per day for at least 3 daysA permanent source with secured water rights, off-grid pumping and treatment, plus stored reserve for the full 180 days at minimum use.
Backup fuelA generator and a full tankNFPA 110: fuel-quality test at least annually; diesel about 6 to 12 monthsPropane where long storage matters; diesel tested and treated on an NFPA 110 schedule, with tank capacity tied to days of runtime.
BatteriesWherever they fitLithium must not be charged below 32°FBattery banks in conditioned or below-grade rooms that stay above freezing, with low-temperature charge protection.
Food storageShelves in the garageBYU: wheat and rice acceptable after 30+ years sealed without oxygen at room temperature or belowA cool, dark, dry storage vault below grade, held steady year round, with rotation shelving and a root cellar.
Safe room"Reinforced" closetFEMA P-361 and ICC 500: 250 mph wind, 15 lb 2x4 at 100 mphSafe rooms in the residence built to FEMA P-361.
Duration72 hoursU.S. bases: 90 days reported planning goalThe 180-day standard: a full winter with no deliveries, utilities or outside services.

Design targets. Every Styrkholm compound is engineered by licensed professionals for its site and household, and final specifications are set in writing during design. Benchmarks are summarized from the sources below.

Questions

About
the Spec.

Are these specifications guaranteed for every project?

They are Styrkholm's design targets. Every compound is engineered by licensed professionals for its own site, soil, climate and household, and the final specifications are set in writing during design.

Why publish our standards?

Because the industry rarely does. Buyers should be able to compare builders on numbers: air per person, protection factor, radon levels, days of water and fuel. We would rather be measured than trusted.

Where do the benchmarks come from?

Swiss civil protection, FEMA, the EPA, NFPA 110, the U.S. Department of Energy, Ready.gov, Oak Ridge National Laboratory's shelter research and BYU's food storage research. Each is linked below.

Hold us to it.

Bring this page to your consultation. We will show you how each number is met on your land.

Request a Private Consultation